Medical Wires, Cables

Medical cables and cable assemblies offered by Octel Cables are designed to be flexible and withstand handling from the medical staff and patients.
Medical cables are constructed using stranded copper and high strength copper alloy conductors as well as precision shielding and jacketing technology, and work together to provide highly flexible, durable and reliable Medical Wire and Medical Cable Assemblies. Our specialized cable constructions are available off the shelf in small and larger quantities, while custom cable configurations can also be supplied to customer specifications.

- Patient monitoring cables.
- Medical cables and electrodes for EEG, ECG, EKG & EMG studies.
- Medical cables for Sleep Studies.
- Custom medical cables and touch proof connectors for various medical devices.
- Cables for EMS, rescue, police & media communications.
- Cables and connectors for custom applications
Solar Cables

Application
Double insulated, cross-linked cables for photovoltaic power applications. This cable is designed to meet the varying needs of the Solar Industry. Applications include connection to PV module junction boxes to array junction box
Temperature Range
Ambient temperature :-40deg C to +90deg C
Max. temperature at conductor :120 deg C
Construction
Conductor : Annealed Tinned Copper as per EN 60228 Class-5
Insulation : XLPE/PVC/ Cross linked Halogen Free Compound
Sheath : XLPE/PVC/ Cross linked Halogen Free Compound
Voltage: 1.8 kV DC- 0.6/1 kV AC
Solar Cables (as per IS 7098 Part1)
Flexible Annealed Tinned Conductor XLPE Insulated & PVC ST-2 Sheathed Cable |
Area(Sqmm) |
Max.Cond.Resistance Ohm/km |
Conductor Dia mm(max) |
Insulation XLPE |
Sheath Thickness PVC |
Overall Diameter(mm)+/-0.5 |
(Amp)Current Carrying Capacity(Air) |
1.5 |
13.7 |
0.26 |
0.70 |
0.90 |
5.0 |
26 |
2.5 |
8.21 |
0.26 |
0.70 |
0.90 |
5.5 |
35 |
4 |
5.09 |
0.31 |
0.70 |
0.90 |
6.0 |
45 |
6 |
3.39 |
0.31 |
0.70 |
0.90 |
6.5 |
58 |
|
Other sizes also available on demand Upto 240sqmm |
Solar Cables (as per IS 694)
Flexible Annealed Tinned Conductor PVC HR Insulated & PVC HR FR Sheathed Cable |
Area(Sq mm) |
Max. Cond. Resistance Ohm/km |
Conductor Dia mm (max) |
Insulation PVC HR FR |
Sheath Thickness PVC HR FR |
Overall Diameter (mm) +/-0.5 |
(Amp) Current Carrying Capacity (Air) |
1.5 |
13.7 |
0.26 |
0.60 |
0.90 |
5.0 |
29 |
2.5 |
8.21 |
0.26 |
0.70 |
0.90 |
5.5 |
40 |
4 |
5.09 |
0.31 |
0.80 |
0.90 |
6.5 |
50 |
6 |
3.39 |
0.31 |
0.80 |
0.90 |
7.0 |
64 |
|
Other sizes also available on demand Up to 240sq mm |
Solar Cables (as per reference TUV Specification 2 Pfg 1169/08.2007)
Flexible Annealed Tinned Conductor XL-Halogen Free Insulated & XL-Halogen Free Sheathed Cable |
Area(Sq mm) |
Max. Cond. Resistance Ohm/km |
Conductor Dia mm (max) |
Insulation |
Sheath Thickness |
Overall Diameter (mm) +/-0.5 |
(Amp) Current Carrying Capacity (Air) |
1.5 |
13.7 |
0.26 |
0.70 |
0.90 |
5.0 |
32 |
2.5 |
8.21 |
0.26 |
0.70 |
0.90 |
5.5 |
41 |
4 |
5.09 |
0.31 |
0.70 |
0.90 |
6.0 |
54 |
6 |
3.39 |
0.31 |
0.70 |
0.90 |
6.5 |
70 |
|
Other sizes also available on demand Up to 240sq mm |
RS-485 Cables
32 AWG stranded (7×32) TC conductors, polyethylene insulation, twisted pairs, overall Alu-mylar (100% coverage) + TC, Inner Sheath, GI Armour & Overall Jacket

Conductor |
Fine Stranded Tinned Copper Conductor |
Insulation |
PVC , PE , PP Color or number coded. |
Fillar |
PVC , PE , PP (optional) |
Shield |
Shield with aluminum – mylar tape 100% coverage . |
Drain Wire |
7/20 AWG or 7/28AWG Stranded Tinned Copper Conductor |
Braiding |
Tinned copper Conductor braid shield 90% coverage. |
Inner Sheath |
PVC, LSZH (optional) |
Armouring |
Galavanised round wire armouring (optional) |
Outer Jacket |
PVC, LSZH |

Operating Temperature Range |
-15 deg C to +80deg C |
Temperature Range |
80 deg C |
Voltage Rating |
300 V |
Min. Bending Radius |
15 x D |